SK9200 Electrolyte analyzer

鈼 Automatic electric potential tracking and correcting software to ensure the stable performance.
鈼 Automatically detect and filter tiny bubbles to avoid clog and ensure accurate measurement.
鈼 Real-time diagnostic of system working status. Waste liquid automatic detection and alarming.
鈼 Automatic calibration and two-point correction to adjust slope and intercept.
鈼 Wave theory flusing method and direct flushing pipe method to avoid block and crossed contamination.
LEARN MORE

Manufacturers Optical System Olympus Microscope CX23, Olympus CX43 Biological Microscope cx33 Oly

鈼 Heory:Biological Microscope
鈼 Drawtube:BINOCULAR or TRINOCULAR
鈼 Optical system:UCIS infinity independent achromatic optical system
鈼 Eyepiece:WF 10X Plan Eyepieces, 20mm field of view, high eye point
鈼 C-adapter:1x c-mount 鈼 Simple polarize device:analyzer and polarizer
鈼 Lighting system:built-in 5W LED lamp (color temperature 6300K)
鈼 ZQ480:Quadruple nosepiece, inward facing
鈼 JG2C:Abbe condenser NA1.25
鈼 LED-0005:5W LED lamp
LEARN MORE

Determination of Fructose in Seminal Plasma (Fructose)

[Test principle]
Fructose of seminal plasma is dehydrogenated by the specific enzyme to form 5-keto fructose, and the product forms a formamidine compound under the action of hydrogen donor, and its absorbance is proportional to the content of fructose in the seminal plasma.
[Validity Period]
The kit is stored at 2-8 掳C for 12 months. The other components except fructose solution can be stored at 2-8 掳C for 45 days after opening. The kit must be used within the validity period.
LEARN MORE

Determination of Acid Phosphatase level in Seminal Plasma (ACP)

[Test principle]
Under acidic conditions, acid phosphatase acts on p-nitrophenol phosphate, which hydrolyzes to release p-nitrophenol (PNP), which forms a yellow compound in an alkaline environment with an absorbance at 405 nm and sample acid phosphate. The enzyme activity is directly proportional.
[Validity Period]
The kit is stored in the environment at 2-8 掳C, and the expiration date is 12 months. After storage at 2-8 掳C after opening, it can be used for 45 days. The kit must be used within the validity period
LEARN MORE

Determination of Acrosin Activity in Human Sperm (Acrosin)

[Test principle]
The arginine amidase activity in the sperm acrosome reflects the activity of all acrosomal enzymes. Arginine amidase is decomposed to produce yellow p-nitroaniline by using N伪-benzoyl-DL-arginine-蟻-p-nitroanilide (BAPNA) as a substrate, and the amount of the product can be used to calculate the refined ammonia. Acid amidase activity
[Validity Period]
The kit should be stored at 2-8 掳C in the dark, valid for 12 months; 2-8 掳C after opening, valid for 3 months, the kit must be used within the validity period.
LEARN MORE

Determination of the citric acid level in seminal plasma (Citric)

[Test principle]
The citrate lyase decomposes citric acid into a keto acid. The reaction product of the latter with a coupling agent has a maximum absorption peak at a wavelength of 340 nm, and its absorbance value is proportional to the citric acid content of the seminal syrup.
[Validity Period]
The kit is stored in the dark at 2-8 掳C. The expiration date is 12 months. The other components except the enzyme solution can be stored at 2-8 掳C for 45 days after opening. The kit must be used within the validity period.