鈼 Up to constant 180 tests per hour.
鈼 Optional for external bar code reader.
鈼 30 positions for samples and 60 postions for reagents.
鈼 Automatic probe cleaning, liquid level detection, collision protection.
鈼 Reversed optic system with 8 wavelengths.
鈼 Refrigerated reagent and sample compartment.
">
undefined
undefined
undefined
undefined
undefined
+
  • Specifications
  • Parameter
  • Accessories
  • Download
    • Commodity name: Sinothinker SK6000 biochemical analysis system chemistry analyzer
    • Commodity ID: SK6000

    鈼 Discrete, random access, full automated.
    鈼 Up to constant 180 tests per hour.
    鈼 Optional for external bar code reader.
    鈼 30 positions for samples and 60 postions for reagents.
    鈼 Automatic probe cleaning, liquid level detection, collision protection.
    鈼 Reversed optic system with 8 wavelengths.
    鈼 Refrigerated reagent and sample compartment.

    Product Description
     
     
     

    Feature:
    Discrete, random access, full automated.
    Up to constant 180 tests per hour.
    Optional for external bar code reader.
    30 positions for samples and 60 postions for reagents.
    Automatic probe cleaning, liquid level detection, collision protection.
    Reversed optic system with 8 wavelengths.
    Refrigerated reagent and sample compartment.


    Operating system:
    English operating system: Windows 2000, windows XP, windows7, windows8, windows10.
    Make print format and content freely, provide several common formals.
    Special user management password, rational distribution of user operation permissions.
    RS-232 standard interface, support for intranet, remote print report.
    Optional various databasses, autosave, automatic backup, save all kinds of data permanently.
    Real-time monitoring of sample tray, reagent tray, reacting tray; real-time display of reaction temperature, reagent allowance,
    reaction curve, calibration curve and quality control chart.
    Check and judge reaction endpoint, reaction linear interval, substrate exhaustion, reagent blank absorbance, etc.


    Reagents/ sample handing:
    Reagent/sample tray: 30 positions for reagents and 60 positions for samples in refrigerated compartment (4~16鈩?.
    Reagent/sample probe: liquid level detection, collision protection and inventory checking.
    Probe cleaning: automatic washing for both interior and exterior carry-over<0.1%


    Reaction cuvettes cleaning system:
    Using unique high efficiency water cleaning method, low carry-over.

    Sampling and mixing system:
    Sample capacity: 2-30ul, 0.1ul increasing.
    Sample probe: sharing with the reagent probe, the inner and auter walls are highly polished, with the function of liquid level
    detection, tracking and collision protection, sample probe matching special cleaning liquid, prevent cross contamination.
    Reagent capacity: 20-300ul, 0.1ul creasing.
    Reagent probe: sharing with the sample probe.
    Reagent bottle: reagent bottles with volume of 15ml, 20ml, 30ml, 50ml, 60ml, 70ml can be used, the dead volume is less than 1ml.
    Mixing bar: independent mixing bar, special material, surface treatment using teflon, not hanging liquid, thoroughly clean before
    and after mixing to prevent cross contamination.


    Calibration and quality control:
    Quality control type: real time quality control, daily quality control, day to day quality control.
    Quality control charts L-J, cumulative, twin plot, the quality control rules are arbitrarily formulated by default to westguard
    multiple rules.
    The calibration type: linear and nonlinear. Logit-4P, Logit-5P, Spline, exponent, polynomial, factor method automatically check
    the calibration curve and select the best calibration type of the fitting degree automati-cally.

     
     
    working mode
     
    discrete/random access
     
    test speed
     
    test speed 180T/H (without ISE)
     
    Test principle
     
    absorbance photometry, turbidimetry
     
    Methodology
     
    end-point, fixed-time, kinetic, single/dual reagent chemistries, monochromatic/ bichromatic linear/non-linear, multi-point
    calibration
     
    the longest reaction time
     
    15 minutes
     
    minumum reaction volume
     
    150ul
     
    cuvettes material
     
    plastics (quartz glass can be selected), 81 cuvettes have the function of automatically deducing.
     
    reagent and sample blanks linear range of absorbance
     
    0-3.8Abs, halogen light source using time≥2000 hours
     
    Wavelength
     
    340nm, 405nm, 450nm, 510nm, 546nm, 578nm, 630nm, 670nm
     
    Refrigeration system
     
    water medium uniform refrigeration technology
     
    Reagent storehouse temperature
     
    4-16鈩傸/span>
     
    Reaction temperature
     
    37±0.2鈩傸/span>
     
    Water consumption
     
    7L/hour
     
    Power supply
     
    200~240V 50/60HZ 600W
     
    Dimension
     
    834mm8643mm8756mm
     
    Rough weight
     
    91kg
     
    Net weight
     
    65kg
     
    Temperature fluctuation
     
    ±0.1鈩傸/span>
     
     
    Customer Feedback
     
     
     
     
    Company Profile
     
     
     
     
     
     
    Exhibition
     
     
     
     
    Packing and Delivery
     
     
     
    FAQ
     

     

     

    Q: What part does this machine ?
    A:3 part .

    Q: Double chambers or single chamber ? how many samples per hour ?
    A: 60T/H(two test chamber),30T/H(single test chamber)

    Q: How many parameters does it have ? and open reagent ?
    A:20 parameters + 3 color histograms ,open reagent?

    Q: Does it test human or vet ??
    A:Human (also have vet model )

     

    Q:Do you sale reagent ??
    A:Yes ,one set including 20L Diluent ,10 L Rinse and 500 ml Lyse?

    Q:How about after-sale serive ?
    A:We will send you any parts within 15 months warranty ,and supply you technology support for long time ,solve problem as soon as possible .

    Q:What's the minimum order quantity (MOQ)?
    A:For most of our medical products, even order for only one unit is warmly welcomed.

    Q: Can you do OEM/ private label?
    A: Of course we can do OEM/private label for you.

     

    Q: What's your delivery time?
    A: Generally it is 3 days if the goods are in stock.
    Or it is 7 days if the goods are not in stock, it is according to quantity.

    Q: How to ship the order?
    A: Please inform us your instruction, by sea, by air or by express, any way is ok for us. We have very professionalforwarder to provide the best shipping cost, service and guarantee.

    Q: What is your terms of payment ?
    A: We accept T/T ,LC,Western Union ,Escrow ,Paypal and more.Please suggest your preferred payment method.

     
     
     
     
     
     

     

     

    Key words:
    • SK6000

Inquiry

%{tishi_zhanwei}%